LAIRUN Cleanroom ComponentsDoors · Windows · Ceiling · Aluminium Profiles
EN ▾

Vision panels and opening sizes

Evidence on this page: Brochure dimensions: single-leaf 800 and 950 mm, unequal-leaf 1200 and 1350 mm, double-leaf 1500 and 1800 mm, height 2100 mm · Leaf swing: 0 to 170 degrees · Vision panels: 250×650 mm, 450×650 mm, 400×600 mm · All sizes on this page are brochure dimensions.
Send your door opening sizes and leaf requirements for a component check
DOOR-LEAF SECTION RULER
1800 — double-leaf opening
1500 — double-leaf opening
1350 — unequal-leaf opening
1200 — unequal-leaf opening
950 — single-leaf opening
800 — single-leaf opening
2100 — opening height
Brochure dimensions

This page is the single size reference for cleanroom doors on this site, and every size on it is a brochure dimension. Brochure dimensions describe the sizes listed in the product brochure; they are a reliable starting schedule, not a promise that every size suits every wall, and any size outside the listed range should be confirmed in the inquiry. Keeping all door sizes on one page, with the brochure source stated, prevents the common error where a size quoted for one leaf arrangement is silently applied to another.

Opening widths are listed by leaf arrangement. Single-leaf openings are 800 mm and 950 mm. Unequal-leaf openings are 1200 mm and 1350 mm. Double-leaf openings are 1500 mm and 1800 mm. The height for these openings is 2100 mm. The leaf swing is stated as 0 to 170 degrees, which is the opening range of the leaf rather than a claim about the clear space around the door; the clear space on each side of the opening should still be checked on the room plan.

Vision panel sizes are 250 by 650 mm, 450 by 650 mm, and 400 by 600 mm. The vision panel itself is an anti-fog double glazed toughened glass panel set in the shared leaf structure, and the size should be chosen per opening: a personnel door, a transfer door, and a viewing door do not need the same vision area, and the schedule should record the size per opening rather than applying one size across the project. Locks and closers are covered on their own page, and the frame and sealing system is covered on its own page, so this page stays a size reference and does not duplicate their specifications.

When a project mixes leaf arrangements, schedule each opening on its own line with its arrangement, its width, its height, and its vision panel size. That discipline keeps the factory schedule, the lock schedule, and the vision panel schedule consistent, and it makes any non-brochure size visible as an exception to confirm rather than a silent assumption.

Brochure size tables

Leaf arrangementBrochure widthsBrochure height
Single-leaf800 mm, 950 mm2100 mm
Unequal-leaf1200 mm, 1350 mm2100 mm
Double-leaf1500 mm, 1800 mm2100 mm
Vision panelSize
Vision panel A250×650 mm
Vision panel B450×650 mm
Vision panel C400×600 mm

All sizes on this page are brochure dimensions.

How to read the specifications on this page

Dimensions and construction details on this page follow the Lairun product description for the component family shown. Door opening sizes quoted on this site are brochure dimensions: they describe the opening sizes listed in the product brochure, and any non-standard size should be confirmed in the inquiry. Aluminium profile codes are listed by code only; no profile dimension is stated where the product description does not give one. Items that the product description does not specify are marked for inquiry confirmation rather than described as available options, so buyers are not led to assume a mechanism, a load figure, or a material variant that has not been evidenced.

What to put in your inquiry

Send the opening sizes you need, the leaf arrangement, the surface finish you prefer, and the ceiling layout where the components will be installed. State the quantities per size, the site conditions, and the delivery location so the component list can be checked line by line. Where this page lists an item as subject to confirmation, include that item explicitly in your message so it is answered before any order is placed. Please confirm the minimum order quantity and the lead time in your inquiry, because this site does not publish those figures. Certificates are available upon request; please ask for the documents you need and state which project they are for.